Supco ATP1 Attc Pro ®
Features/Benefits:
- Adjustable from 14″ to 24′
- 20 foot cable length
- Integrated locking hook
- Lifts up to 250 lbs.
- Sturdy steel construction
- Equipment straps included
- Carrying case included
Features/Benefits:
Uniweld NV1 NitroVue™ simplifies the purging of nitrogen during the brazing of copper tubing in Air Conditioning and Refrigeration systems with an “easy” to read flow indicator label and a precision adjustable valve to control the low flow of nitrogen gas.
The bright orange float ball and tube are fortified and protected in the aluminum body with wide open windows for a clear view.
The easy to see orange float ball visually confirms the nitrogen is flowing and allows the technician to first “PURGE” the copper lines at 20+ SCFH and then reduce the flow to “BRAZE” at 3-5 SCFH during the brazing process thus conserves its consumption and reduces operating cost.
The nitrogen must be flowing to displace the oxygen inside the tubing during the brazing process, preventing internal oxidation and the resulting scale. Scale build up inside the tubing can cause blockage in the TXV and within the Air Conditioning and Refrigeration system resulting in premature failure. If the ball does not rise in the tube there is no flow of nitrogen only static pressure and oxygen is not being displaced.
The NV1 must be connected to a Nitrogen Regulator with the delivery pressure set at 60 PSI to control the nitrogen gas pressure.
The NV1 is protected from over pressure with a reseatable safety blow off that opens at 200+ PSI.

CPS BLACKMAX Tube Expanders Kit Now Available
1/4, 5/16, 3/8, 1/2, 5/8, 3/4, 7/8, 1, 1-1/8

Veto Tech Pac LT
QT2510: 0.5 oz.
Qt2511: 4 oz.
QwikInjector® is used to drive any liquid (such as QwikShot®) into the low side of a charged system. It is compatible with all refrigerants and oils, including R-410A. This rugged aluminum tool is used with any ordinary gauge set to inject liquid additives into the system.

Qwik Injector Additive Injection Tooll

Veto Pro Pac MC Bag

Juglugger
Shoulder pads on today’s HVAC tools are just not comfortable. We spent hundreds of hours selecting, testing, and retesting various types of padding to meet the expectations of those who need to carry heavy objects day after day. The rugged shoulder pad on our refrigerant strap is covered with high quality, heavy duty nylon and special anti-slip fabric to keep it secure on your shoulder. The Juglugger strap wraps securely around our shoulder comfortably and securely without binding, quickly and securely locks to heavy refrigerant cylinders and equipment, and easily adjusts length to minimize twisting and fiddling.
Your Juglugger refrigerant strap connects to gas cylinders and other heavy objects using heavy gauge steel snap links. They are easy-on and easy-off, but lock in place to secure the load. Everything about the Juglugger is over-designed to exceed the expectations of the hardworking HVAC technicians who put our product to the test day-in and day-out. You simply will not find a better, more rugged, or longer lasting carrying strap … Period!
Our refrigerant strap is designed to comfortably and easily attached to disposable gas cylinders, reclaim cylinders, and European approved refrigerant cylinders… not to mention many other heavy object you need to get to the job site!

Do More with the Pressures You Need with the New Fieldpiece Dual Port Manometer and Pressure Switch Test
Correct pressure switch operation is integral to the safety of a furnace environment. The SDMN6 is a dual-port manometer that also accurately tests pressure switches by simulating a draft with an internal pump.
The SDMN6 allows you to test pressure switches the right way.
Adjust the pump’s speed to create a negative pressure (vacuum). The red LED indicates when the switch closes. View the closing and opening pressures directly on the LCD.
The dual-port manometer measures ±60 inches of water column, high enough for gas manifold pressures.
Check building pressurization with static pressure resolution of 0.01”WC. View P1-P2 in the bottom line of the display for checking the performance of a blower.
The SDMN6 dual-port manometer measures gas and static pressure and also accurately tests pressure switches by simulating a draft with an internal pump. A pressure switch is a safety device that prevents the furnace from running in an unsafe manner. The SDMN6 tests the pressure switch to determine if it is working properly, or if it is starting to fail which can cause the furnace to run in an unsafe manner. Plus, with the SDMN6 you can easily calibrate any adjustable pressure switch to manufacturers’ specification, so there’s no need to carry a large variety of pressure switches on your truck.
The Dual Port Manometer has the ranges to measure gas pressure and the resolution needed to measure static pressure. Ideal for HVACR field service technicians, the SDMN6 can determine if the gas pressure coming into the house or out of the regulator are correct. The SDMN6 measures gas pressure up to 60″ water column (WC) with a resolution of 0.1″ WC. In addition, the unit measures both positive and negative pressure, which is used for measurement on vacuum control lines. The unit will take differential pressure readings and display the difference between P1 and P2 at all times in the lower right corner of the easy-to-read LCD. Four different measurement scales can be used: inches of water column, millimeters of water column, mBar, and PSI.
The SDMN6 also has a zero adjust to zero out the meter in different ambient pressures. It has a hold button to hold the currently displayed reading. The auto-power-off function conserves battery life, but can be disabled if desired.
In the static pressure mode, the unit can measure up to 2″WC with resolution to 0.010″WC, which enables a technician to measure small differences in air (or static) pressure.
Testing with the SDMN6 Dual Port Manometer and Pressure Switch Tester